Quick Answer
Calculate Radiographic Geometric Unsharpness (ug) per ASTM E94 / ISO 17636
Calculator
Need Equipment or a Supplier for This Project?
Use your calculation result to continue with equipment selection, supplier discovery, engineering support, or project evaluation.
Find Engineering Solutions →Result Interpretation
Radiographic Geometric Unsharpness (ug) per ASTM E94 / ISO 17636 calculator computes Geometric Unsharpness in mm using the defined engineering formula and the input values provided. Geometric Unsharpness is expressed in mm. No universal acceptance threshold is defined by this calculator.
Worked Example
Verified calculation
Given:
- Focal Spot Size = 0.5
- Object-to-Detector Distance = 400
- Source-to-Object Distance = 800
Expected Result:
- Geometric Unsharpness = 0.25
Engineering Interpretation:
Under the given input conditions, the calculated result is: Geometric Unsharpness = 0.25 mm.
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from deterministically validated test cases.
Formula / Method
geometric unsharpness = focal spot size * (object-to-detector distance / source-to-object distance)Formula family: formula_ndt_radiographic_geometric_unsharpness_ug_per_astm_e94_iso_17636
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| F | Focal Spot Size | INPUT | Focal Spot Size |
| ODD | Object-to-Detector Distance | INPUT | Object-to-Detector Distance |
| SOD | Source-to-Object Distance | INPUT | Source-to-Object Distance |
| ug | Geometric Unsharpness | OUTPUT | Geometric Unsharpness |
Calculation Steps
- Enter the focal spot size in mm.
- Enter the object-to-detector distance in mm.
- Enter the source-to-object distance in mm.
- Step 1: Compute geometric unsharpness.
- Read the geometric unsharpness (mm) from the results.
Engineering Summary
Calculate Radiographic Geometric Unsharpness (ug) per ASTM E94 / ISO 17636
Frequently Asked Questions
What does this calculator calculate?
The Radiographic Geometric Unsharpness (ug) per ASTM E94 / ISO 17636 calculator estimates Geometric Unsharpness based on the input parameters you provide
Why is focal spot size important in this calculation?
focal spot size is directly proportional to geometric unsharpness. When you enter focal spot size in mm, the calculator uses it in the engineering formula to compute the output
How should I interpret the result geometric unsharpness?
The calculator outputs geometric unsharpness in mm. The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: Focal Spot Size (mm), Object-to-Detector Distance (mm), Source-to-Object Distance (mm). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment
Related Tools
ASME Section V Article 4 IQI Sensitivity Percentage Calculator
Ultrasonic Near-Field Resolution Limit for Minimum Resolvable Flaw Size in Steel calculator
Phased Array Axial Depth of Field (Steel) calculator
Ultrasonic Beam Spread Angle for Angle Beam Probes in Steel (ASME Section V Art. 4) calculator
Ultrasonic Beam Spread (Divergence) Angle for Circular Probes in NDT calculator
Ultrasonic Near-Field Length for Straight Beam Probes calculator
Browse More Tools
Explore the full index of engineering calculators on this vertical site.